{"id":1323,"date":"2016-07-11T17:08:37","date_gmt":"2016-07-11T17:08:37","guid":{"rendered":"https:\/\/multiserveisjoannet.es\/non-return-valve-in-barcelona-sewer-systems\/"},"modified":"2026-07-23T15:45:50","modified_gmt":"2026-07-23T15:45:50","slug":"non-return-valve-in-barcelona-sewer-systems","status":"publish","type":"page","link":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/","title":{"rendered":"Non-return valve in Barcelona sewer systems"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Installation of a non-return valve in sewer systems<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>Non-return valve installation project for wastewater sewer systems in Barcelona<\/strong><\/p>\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Instalaci\u00f3n de valvula anti retorno en v\u00edas fecales residuales\" width=\"1060\" height=\"596\" src=\"https:\/\/www.youtube.com\/embed\/vKI2tmo37Zc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Instalaci\u00f3n de valvula anti retorno residuales\" width=\"1060\" height=\"596\" src=\"https:\/\/www.youtube.com\/embed\/NEA9rnEhGtU?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n<h2 class=\"wp-block-heading\">Non-return valve for wastewater sewer systems<\/h2>\n\n<p class=\"wp-block-paragraph\"><b>Non-return valves<\/b>, also known as <b>check valves, one-way valves or non-return<\/b> <i>check <\/i>valves, are designed to completely stop the flow of a fluid in one direction, whether gas or liquid, while allowing it to pass freely in the opposite direction. Their advantage is that the disc or obturator only needs to travel a short distance to reach the fully open position. It has the advantage of requiring only minimal disc or obturator travel to reach the fully open position.<\/p>\n\n<p class=\"wp-block-paragraph\">They are used when a pipeline in service needs to remain pressurised while the supply is depressurised. Fluid flowing from the inlet towards the outlet can pass freely, while flow in the opposite direction is blocked. They are also commonly referred to as <b>one-way valves<\/b>.<\/p>\n\n<p class=\"wp-block-paragraph\">Non-return valves are widely used in pipework connected to pumping systems to prevent water hammer, particularly in the pump discharge line.<\/p>\n\n<h2 class=\"wp-block-heading\">Image gallery<\/h2>\n\n<figure class=\"wp-block-gallery columns-3 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg\" alt=\"Non-return valve for sewage systems in Barcelona\" data-id=\"352\" class=\"wp-image-352\" srcset=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg 1024w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-300x225.jpg 300w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-768x576.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><img decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-2.jpg\" alt=\"Installation of a valve for sewage systems in Barcelona\" data-id=\"353\" class=\"wp-image-353\" srcset=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-2.jpg 576w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-2-169x300.jpg 169w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona-2-768x1364.jpg 768w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona3.jpg\" alt=\"Non-return valve installation in Barcelona\" data-id=\"354\" class=\"wp-image-354\" srcset=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona3.jpg 1024w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona3-300x169.jpg 300w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona3-768x432.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><img decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona4.jpg\" alt=\"Non-return valve installers\" data-id=\"355\" class=\"wp-image-355\" srcset=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona4.jpg 576w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona4-169x300.jpg 169w, https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona4-768x1364.jpg 768w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/figure><\/li><\/ul><\/figure>\n\n<h2 class=\"wp-block-heading\">Types of valves:<\/h2>\n\n<h3 class=\"wp-block-heading\">Swing check valve<\/h3>\n\n<p class=\"wp-block-paragraph\">A swing check valve uses a hinged flap as the closure element and shuts off the flow by gravity when the fluid travels in the undesired direction (see the figure above). These valves operate by gravity and must therefore be installed in a specific position.<\/p>\n\n<h3 class=\"wp-block-heading\">Spring-loaded check valve<\/h3>\n\n<p class=\"wp-block-paragraph\">These valves do not need to be installed in a specific position, as their operation does not depend on gravity. There are two types. <\/p>\n\n<p class=\"wp-block-paragraph\">In the first type, a spring calibrated to a specific pressure holds a closure element against a sealing ring. The water pressure overcomes the resistance of the spring, allowing the fluid to pass through, but the spring closes the valve when the fluid flows in the opposite direction.<\/p>\n\n<p class=\"wp-block-paragraph\">The other type, known as a dual-plate check valve, consists of two semi-circular plates that rotate about a shaft and close the passage when aligned. A spring holds them in position but does not contribute to the sealing action. It produces a lower pressure loss than the previous type, although its seal is less watertight.<\/p>\n\n<h3 class=\"wp-block-heading\">Piston check valve<\/h3>\n\n<p class=\"wp-block-paragraph\">A piston fitted with a closure element rests against the sealing ring and is housed within a cylindrical chamber. When the fluid flows in the correct direction, it lifts the piston. When the flow reverses, the piston seats against the ring. The shape of the piston seat allows the reverse water pressure to press the closure element firmly against the sealing ring. As with the first type, it must be installed in the correct position, as it also operates by gravity.<\/p>\n\n<h3 class=\"wp-block-heading\">Ball check valve<\/h3>\n\n<p class=\"wp-block-paragraph\">This is a special type used at the ends of well extraction pumps. For example, a ball rests against the sealing ring. When the pump draws water from the tank or well, the ball rises and moves into a side chamber so that it does not obstruct the flow. When the pump stops, the ball returns by gravity to its closed position, preventing the pipe from emptying.<\/p>\n\n<p class=\"wp-block-paragraph\">Further information: <a rel=\"noopener noreferrer\" href=\"https:\/\/es.wikipedia.org\/wiki\/V%C3%A1lvula_antirretorno\" target=\"_blank\">Wikipedia<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Installation of a non-return valve in sewer systems Non-return valve installation project for wastewater sewer systems in Barcelona Non-return valve for wastewater sewer systems Non-return valves, also known as check valves, one-way valves or non-return check valves, are designed to completely stop the flow of a fluid in one direction, whether gas or liquid, while [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1323","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Installation of a non-return valve in wastewater sewer systems<\/title>\n<meta name=\"description\" content=\"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Installation of a non-return valve in wastewater sewer systems\" \/>\n<meta property=\"og:description\" content=\"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-23T15:45:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/\",\"url\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/\",\"name\":\"Installation of a non-return valve in wastewater sewer systems\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/multiserveisjoannet.es\\\/wp-content\\\/uploads\\\/2016\\\/07\\\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg\",\"datePublished\":\"2016-07-11T17:08:37+00:00\",\"dateModified\":\"2026-07-23T15:45:50+00:00\",\"description\":\"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/#primaryimage\",\"url\":\"https:\\\/\\\/multiserveisjoannet.es\\\/wp-content\\\/uploads\\\/2016\\\/07\\\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg\",\"contentUrl\":\"https:\\\/\\\/multiserveisjoannet.es\\\/wp-content\\\/uploads\\\/2016\\\/07\\\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/non-return-valve-in-barcelona-sewer-systems\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Non-return valve in Barcelona sewer systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/\",\"name\":\"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas\",\"description\":\"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas\",\"publisher\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#organization\",\"name\":\"Multiserveisjoannet\",\"url\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/multiserveisjoannet.es\\\/wp-content\\\/uploads\\\/2016\\\/04\\\/joanet.png\",\"contentUrl\":\"https:\\\/\\\/multiserveisjoannet.es\\\/wp-content\\\/uploads\\\/2016\\\/04\\\/joanet.png\",\"width\":400,\"height\":400,\"caption\":\"Multiserveisjoannet\"},\"image\":{\"@id\":\"https:\\\/\\\/multiserveisjoannet.es\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/desatascosbarcelona24h\\\/\",\"https:\\\/\\\/es.pinterest.com\\\/reformasb\\\/\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCuE7O9dZpG4Ka3cm0a56_ww\",\"https:\\\/\\\/www.flickr.com\\\/people\\\/desatascosbarcelona\\\/\",\"https:\\\/\\\/desatascos-barcelona-urgencias.blogspot.com\\\/\",\"https:\\\/\\\/multiserveisjoannet.tumblr.com\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/reformasbarcelona24h\",\"https:\\\/\\\/vimeo.com\\\/camioncuba\",\"https:\\\/\\\/www.instagram.com\\\/multiserveisjoannet\\\/\",\"https:\\\/\\\/bsky.app\\\/profile\\\/serveisjoannet.bsky.social\",\"https:\\\/\\\/www.threads.net\\\/@multiserveisjoannet\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Installation of a non-return valve in wastewater sewer systems","description":"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/","og_locale":"en_US","og_type":"article","og_title":"Installation of a non-return valve in wastewater sewer systems","og_description":"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.","og_url":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/","og_site_name":"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas","article_modified_time":"2026-07-23T15:45:50+00:00","og_image":[{"width":1024,"height":768,"url":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/","url":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/","name":"Installation of a non-return valve in wastewater sewer systems","isPartOf":{"@id":"https:\/\/multiserveisjoannet.es\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/#primaryimage"},"image":{"@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg","datePublished":"2016-07-11T17:08:37+00:00","dateModified":"2026-07-23T15:45:50+00:00","description":"Multiserveis Joannet: Installation of a non-return valve in wastewater sewer systems in Barcelona. An inspection chamber cover is intended for the siphon chamber.","breadcrumb":{"@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/#primaryimage","url":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg","contentUrl":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/07\/instalacion-valvula-anti-retorno-vias-fecales-residuales-barcelona.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/multiserveisjoannet.es\/en\/non-return-valve-in-barcelona-sewer-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/multiserveisjoannet.es\/en\/"},{"@type":"ListItem","position":2,"name":"Non-return valve in Barcelona sewer systems"}]},{"@type":"WebSite","@id":"https:\/\/multiserveisjoannet.es\/en\/#website","url":"https:\/\/multiserveisjoannet.es\/en\/","name":"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas","description":"Desatascos Barcelona Urgencias Cami\u00f3n Cuba, Arquetas, Fosas S\u00e9pticas","publisher":{"@id":"https:\/\/multiserveisjoannet.es\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/multiserveisjoannet.es\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/multiserveisjoannet.es\/en\/#organization","name":"Multiserveisjoannet","url":"https:\/\/multiserveisjoannet.es\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/multiserveisjoannet.es\/en\/#\/schema\/logo\/image\/","url":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/04\/joanet.png","contentUrl":"https:\/\/multiserveisjoannet.es\/wp-content\/uploads\/2016\/04\/joanet.png","width":400,"height":400,"caption":"Multiserveisjoannet"},"image":{"@id":"https:\/\/multiserveisjoannet.es\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/in\/desatascosbarcelona24h\/","https:\/\/es.pinterest.com\/reformasb\/\/","https:\/\/www.youtube.com\/channel\/UCuE7O9dZpG4Ka3cm0a56_ww","https:\/\/www.flickr.com\/people\/desatascosbarcelona\/","https:\/\/desatascos-barcelona-urgencias.blogspot.com\/","https:\/\/multiserveisjoannet.tumblr.com\/","https:\/\/www.linkedin.com\/in\/reformasbarcelona24h","https:\/\/vimeo.com\/camioncuba","https:\/\/www.instagram.com\/multiserveisjoannet\/","https:\/\/bsky.app\/profile\/serveisjoannet.bsky.social","https:\/\/www.threads.net\/@multiserveisjoannet"]}]}},"_links":{"self":[{"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/pages\/1323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/comments?post=1323"}],"version-history":[{"count":1,"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/pages\/1323\/revisions"}],"predecessor-version":[{"id":1324,"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/pages\/1323\/revisions\/1324"}],"wp:attachment":[{"href":"https:\/\/multiserveisjoannet.es\/en\/wp-json\/wp\/v2\/media?parent=1323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}